SIGENERGY Battery 10.0 kWh
SIGENERGY Battery 10.0 kWh
Low stock: 10 left
- 100% certified
- Ready for Installation
- Fast delivery within NL & BE
Couldn't load pickup availability
The BAT 10.0 is a lithium iron phosphate (LiFePO₄) home/small business storage system module from Sigenergy, part of the SigenStor ecosystem. It is designed for storing solar energy, enhancing self-consumption, providing backup power, and integrating with inverters, EV chargers, EMS, etc.
Technical specifications
| Characteristic | Specification |
|---|---|
| Nominal (gross) capacity | ± 9.04 kWh |
| Usable capacity | ± 8.76 kWh |
| Battery type | Lithium Iron Phosphate (LiFePO₄) |
| Cell specifications | Premium 314 Ah cells; 100% Depth of Discharge (DoD) |
| Continuous charge/discharge capacity | ~ 4,600 W with the 10.0 module |
| Peak power (short-term, ~10s) | ~ 6,700 W peak power (10 seconds) |
| Temperature range operation | -20 °C to +55 °C |
| Storage temperature range | -25 °C to +60 °C |
| Protection class (IP rating) | IP66 – dust and water resistant (outdoor use possible) |
| Dimensions | approx. 767 × 270 × 265 mm (W × H × D) |
| Weight | ~ 78 kg |
| Maximum height / use at height | Permitted up to ~4,000 meters above sea level |
| Use & installation | Wall or floor mounting possible; stackable – maximum 6 modules per “tower”/stack within the same system. |
| Warranty | 10-year product warranty |
Features & Operation
-
-
100% Depth of Discharge : you can fully discharge the BAT 10.0 without any “reserve” being kept (according to the specifications), thus maximizing the usable capacity.
-
Stackable / modular design : you can combine multiple modules within one SigmanStor system – up to 6 modules per stack – and multiple stacks in parallel for larger capacity.
-
Safety layers : there is a “5-layer” safety system, with built-in monitoring of temperature, voltage, etc. In addition, the cells are of premium quality.
-
Cooling : Natural convection (so without active fans) to dissipate heat during normal use.
-
Integration with app/monitoring : status check via LED indicator on the module and via the mySigen app/platform, for insight into usage, charging/discharging periods, etc.
-
1. This is provided by the battery cell manufacturer. Based on test conditions of 25±2°C, a charge and discharge rate of 0.5C
and an SOH of 60%.
2. Test conditions: 100% depth of discharge, average charge and discharge rate of 0.2C at 25°C, at the beginning of the
lifespan.
3. Refers to the usable energy capacity. The battery must be charged within 7 days of full discharge to maintain
to maintain battery health.
4. SigenStor BC must be used when connecting the Sigen Hybrid SP2/TP2 to the Sigen battery.